{"id":10271913542,"title":"23872","handle":"23872","description":"\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/LED-50W_thumb.png?v=1492003015\" alt=\"Up to 50W of LED\"\u003e\u003c\/p\u003e\n\u003cp\u003eA general purpose panel mounted two channel time switch that offers good functionality along with the flexibility of its mounting options making it an ideal choice for many applications. The key programming feature enables away from site programming and uniform programming of multiple locations. Text based menu system and self explanatory symbols displayed on a large, back-lit dot matrix area to provide two high resolution text lines. Pulse programming allows you to set small bursts (e.g. school bells) in 1 second steps.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 23872 can be extremely quick and easy to program, it can be programmed with supply disconnected and has the ability to program via your computer using Sangamo’s optional Easy Vue software and USB link (25195 – not supplied) or \u003c\/span\u003e\u003cspan\u003eby Bluetooth using the Sangamo Connect Android App and Bluetooth USB Hub (25196). Both require a programming key (25193 – not supplied).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCan be mounted on a panel, surface or DIN rail (95587 Mounting Kit required) making this an adaptable timer for a variety of situations.\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFEATURES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAutomatic sorting of switching times on readout\u003cbr\u003eText based menu \u0026amp; self-explanatory symbols\u003cbr\u003eDisplay with Large dot matrix area to provide two high resolution text lines\u003cbr\u003eQuick \u0026amp; intuitive programmable time switch\u003cbr\u003eElapsed time and pulse counter\u003cbr\u003eProgrammable by PC or Sangamo Connect Android App (additional accessory required)\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003cspan\u003e 230V, 50-60Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e 0.5-1.2W (depending on switching status)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eChannel (volt-free)\u003c\/strong\u003e\u003cspan\u003e Channel A: Change-over, Channel B: Normally Open, contact gap less than 3mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003cspan\u003e AgNi\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003cspan\u003e Per Channel 16A \/ 250V~ at cosφ=1 | 10A with inductive load cosφ=0.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMin. Switching Power\u003c\/strong\u003e\u003cspan\u003e 300mW (5V\/5mA)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMax. starting current\u003c\/strong\u003e\u003cspan\u003e 30A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFilament Lamp, Halogen Lamp\u003c\/strong\u003e\u003cspan\u003e 400W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFluorescent Lamp\u003cem\u003e with electron. lamp ballast\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e 100W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFluorescent Lamp\u003cem\u003e with convent. lamp ballast\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e 100W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eLED\u003c\/strong\u003e\u003cspan\u003e (230V~)\u003c\/span\u003e\u003cstrong\u003e\/CFL\u003c\/strong\u003e\u003cspan\u003e 50W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Functions \u003c\/strong\u003e\u003cspan\u003eON; OFF; pulse\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePulse length Pulse function\u003c\/strong\u003e\u003cspan\u003e 00:01 up to 59:59 mm:ss\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMemory Locations\u003c\/strong\u003e\u003cspan\u003e 46\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Interval\u003c\/strong\u003e\u003cspan\u003e 1min.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eTime Base \u003c\/strong\u003e\u003cspan\u003eQuartz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eQuartz Accuracy\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e ≦ ±0.5 sec\/day (Quartz accuracy optimized for typical ambient conditions)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Back-up\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e approx. 10 years\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eProgram Security\u003c\/strong\u003e\u003cspan\u003e Unlimited (E²-PROM)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDisplay \u003c\/strong\u003e\u003cspan\u003eHigh resolution LCD (visable area 7.5cm²)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Ambient Temperature\u003c\/strong\u003e\u003cspan\u003e -30°C to 55°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cspan\u003e Self-extinguishing thermoplastic\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e 72mm x 72mm (to IEC 61554)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cspan\u003e Panel and wall\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of Connection\u003c\/strong\u003e\u003cspan\u003e Screw terminals\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of protection\u003c\/strong\u003e\u003cspan\u003e IP20 to DIN EN 60529\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003cspan\u003e II (when installed according to regulations)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 1BSTU\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDegree of Contamination\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eRated Surge Voltage\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 4kV\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eCertification Mark\u003c\/strong\u003e\u003cspan\u003e VDE\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eWIRING\u003c\/span\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eNot Used – Normally Closed connection\u003c\/li\u003e\n\u003cli\u003eOutput (Load Ch. A) – Normally Open connection\u003c\/li\u003e\n\u003cli\u003eInput (Load Ch. A) – External link 3 to 5 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eNeutral In (Clock)\u003c\/li\u003e\n\u003cli\u003eLive In (Clock)\u003c\/li\u003e\n\u003cli\u003eInput (Load Ch. B) – External link 6 to 5 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eOutput (Load Ch.B) – Normally Open connection\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/23872_large.png?v=1491829649\" alt=\"Sangamo 23872 Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/DM005D-23872.pdf?5825304391359724611\" title=\"Sangamo 23872 Datasheet\" target=\"_blank\"\u003e23872 Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/23871-23872-Instructions.pdf?5825304391359724611\" title=\"Sangamo 23872 Instructions\" target=\"_blank\"\u003e23872 Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=Sv3bQuKic_Q\u0026amp;list=PLPVytCcKzzm4HOtE1Nyq1cl8McT38IPJ4\" title=\"Sangamo 23872 YouTube Video Guides\" target=\"_blank\"\u003eYouTube Video Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/sangamo.myshopify.com\/collections\/astro-suntracker\/products\/easyvue\" title=\"Sangamo EasyVue Software\" target=\"_blank\"\u003eEasyView PC Software\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.sangamo.connect\" title=\"Sangamo Connect on Google Play\" target=\"_blank\"\u003eSangamo Connect Android App\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e","published_at":"2017-04-05T12:41:56+01:00","created_at":"2017-04-05T12:41:59+01:00","vendor":"Sangamo DIN \u0026 Panel","type":"Brands,Panel Mounted Timers,Time Switches","tags":["Battery Reserve_10 Years","Brand_DIN \u0026 Panel","Contact Rating 16A","LED Rating_Up to 50W","Operations_46 Memory Locations","Outputs_2 Channel","Programming Cycle_7 Day","Programming Features_Key Programming","Programming Features_Pulse Programming","Type_Standard Time Switch"],"price":0,"price_min":0,"price_max":0,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41085731590,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"23872","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"23872","public_title":null,"options":["Default Title"],"price":0,"weight":227,"compare_at_price":null,"inventory_quantity":0,"inventory_management":"shopify","inventory_policy":"deny","barcode":"4022709231185","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.sangamo.co.uk\/cdn\/shop\/products\/23872.jpg?v=1531131262"],"featured_image":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/23872.jpg?v=1531131262","options":["Title"],"media":[{"alt":null,"id":3188854784138,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/23872.jpg?v=1531131262"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/23872.jpg?v=1531131262","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: left;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/LED-50W_thumb.png?v=1492003015\" alt=\"Up to 50W of LED\"\u003e\u003c\/p\u003e\n\u003cp\u003eA general purpose panel mounted two channel time switch that offers good functionality along with the flexibility of its mounting options making it an ideal choice for many applications. The key programming feature enables away from site programming and uniform programming of multiple locations. Text based menu system and self explanatory symbols displayed on a large, back-lit dot matrix area to provide two high resolution text lines. Pulse programming allows you to set small bursts (e.g. school bells) in 1 second steps.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 23872 can be extremely quick and easy to program, it can be programmed with supply disconnected and has the ability to program via your computer using Sangamo’s optional Easy Vue software and USB link (25195 – not supplied) or \u003c\/span\u003e\u003cspan\u003eby Bluetooth using the Sangamo Connect Android App and Bluetooth USB Hub (25196). Both require a programming key (25193 – not supplied).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eCan be mounted on a panel, surface or DIN rail (95587 Mounting Kit required) making this an adaptable timer for a variety of situations.\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFEATURES\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003eAutomatic sorting of switching times on readout\u003cbr\u003eText based menu \u0026amp; self-explanatory symbols\u003cbr\u003eDisplay with Large dot matrix area to provide two high resolution text lines\u003cbr\u003eQuick \u0026amp; intuitive programmable time switch\u003cbr\u003eElapsed time and pulse counter\u003cbr\u003eProgrammable by PC or Sangamo Connect Android App (additional accessory required)\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003cspan\u003e 230V, 50-60Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e 0.5-1.2W (depending on switching status)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eChannel (volt-free)\u003c\/strong\u003e\u003cspan\u003e Channel A: Change-over, Channel B: Normally Open, contact gap less than 3mm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003cspan\u003e AgNi\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003cspan\u003e Per Channel 16A \/ 250V~ at cosφ=1 | 10A with inductive load cosφ=0.6\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMin. Switching Power\u003c\/strong\u003e\u003cspan\u003e 300mW (5V\/5mA)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMax. starting current\u003c\/strong\u003e\u003cspan\u003e 30A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFilament Lamp, Halogen Lamp\u003c\/strong\u003e\u003cspan\u003e 400W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFluorescent Lamp\u003cem\u003e with electron. lamp ballast\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e 100W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFluorescent Lamp\u003cem\u003e with convent. lamp ballast\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e 100W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eLED\u003c\/strong\u003e\u003cspan\u003e (230V~)\u003c\/span\u003e\u003cstrong\u003e\/CFL\u003c\/strong\u003e\u003cspan\u003e 50W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Functions \u003c\/strong\u003e\u003cspan\u003eON; OFF; pulse\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePulse length Pulse function\u003c\/strong\u003e\u003cspan\u003e 00:01 up to 59:59 mm:ss\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMemory Locations\u003c\/strong\u003e\u003cspan\u003e 46\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Interval\u003c\/strong\u003e\u003cspan\u003e 1min.\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eTime Base \u003c\/strong\u003e\u003cspan\u003eQuartz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eQuartz Accuracy\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e ≦ ±0.5 sec\/day (Quartz accuracy optimized for typical ambient conditions)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Back-up\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e approx. 10 years\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eProgram Security\u003c\/strong\u003e\u003cspan\u003e Unlimited (E²-PROM)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDisplay \u003c\/strong\u003e\u003cspan\u003eHigh resolution LCD (visable area 7.5cm²)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Ambient Temperature\u003c\/strong\u003e\u003cspan\u003e -30°C to 55°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003cspan\u003e Self-extinguishing thermoplastic\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e 72mm x 72mm (to IEC 61554)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cspan\u003e Panel and wall\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of Connection\u003c\/strong\u003e\u003cspan\u003e Screw terminals\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of protection\u003c\/strong\u003e\u003cspan\u003e IP20 to DIN EN 60529\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003cspan\u003e II (when installed according to regulations)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 1BSTU\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDegree of Contamination\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eRated Surge Voltage\u003c\/strong\u003e\u003cspan\u003e (DIN EN 60730-1) 4kV\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eCertification Mark\u003c\/strong\u003e\u003cspan\u003e VDE\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eWIRING\u003c\/span\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eNot Used – Normally Closed connection\u003c\/li\u003e\n\u003cli\u003eOutput (Load Ch. A) – Normally Open connection\u003c\/li\u003e\n\u003cli\u003eInput (Load Ch. A) – External link 3 to 5 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eNeutral In (Clock)\u003c\/li\u003e\n\u003cli\u003eLive In (Clock)\u003c\/li\u003e\n\u003cli\u003eInput (Load Ch. B) – External link 6 to 5 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eOutput (Load Ch.B) – Normally Open connection\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/23872_large.png?v=1491829649\" alt=\"Sangamo 23872 Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/DM005D-23872.pdf?5825304391359724611\" title=\"Sangamo 23872 Datasheet\" target=\"_blank\"\u003e23872 Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/23871-23872-Instructions.pdf?5825304391359724611\" title=\"Sangamo 23872 Instructions\" target=\"_blank\"\u003e23872 Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=Sv3bQuKic_Q\u0026amp;list=PLPVytCcKzzm4HOtE1Nyq1cl8McT38IPJ4\" title=\"Sangamo 23872 YouTube Video Guides\" target=\"_blank\"\u003eYouTube Video Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/sangamo.myshopify.com\/collections\/astro-suntracker\/products\/easyvue\" title=\"Sangamo EasyVue Software\" target=\"_blank\"\u003eEasyView PC Software\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.sangamo.connect\" title=\"Sangamo Connect on Google Play\" target=\"_blank\"\u003eSangamo Connect Android App\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e"}