{"id":10271709190,"title":"Choice PR2n","handle":"choice-pr2n","description":"\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/backlit-display.png?v=1530536117\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe Choice PR2n 2 channel programmer is designed for separate control of you heating and stored hot water. The heating and hot water programmes are independent of each other. This gives you the opportunity to save money and control you heating in the most energy saving manner possible.The programmer can be configured for 24 hour, 5\/2 day or 7 day operation, and the flexibility of up to three on\/off timings per day.\u003c\/p\u003e\n\u003cp\u003ePre-programmed but can easily be changed to suit your particular lifestyle. Large and clear to read illuminated display. Attractive modern design that will suit all contemporary homes.Suitable for pumped and gravity fed systems.\u003c\/p\u003e\n\u003cp\u003eFor fully pumped central heating systems using mid position valves, spring return valves or power open, power closed valves or Gravity hot water pumped heating systems with or without motorised valves fitted into the domestic hot water primary circuit.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24 hour, 5\/2 day and 7 day selectable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 or 3 ON\/OFF periods selectable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1, 2 or 3 hour boost\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAdvance to next programmed event\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAutomatic Summer\/Winter time change\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStandard wall plate - simple plug in and replace\u003c\/span\u003e\u003cbr\u003ePumped or gravity system selectable\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATION\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 230V AC, 50Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch Rating:\u003c\/strong\u003e 230V AC, 2(1)Amp (per channel)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e 1B , Micro-Disconnection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Lithium Cell CR2032\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e IP30\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastics:\u003c\/strong\u003e Thermoplastic, flame retardant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e Double\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e For fixed wiring only\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackplate:\u003c\/strong\u003e Industry standard\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 140mm x 87mm x 37mm Clock: 12 hour am\/pm, 1 minute resolution, accuracy +\/- 1.5 sec\/day\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBST\/GMT time change:\u003c\/strong\u003e Automatic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Cycle:\u003c\/strong\u003e 24hr, 5\/2day or 7day selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram On\/offs per day:\u003c\/strong\u003e 2on\/off, 3on\/off selectable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram resolution:\u003c\/strong\u003e 10mins Program Selection: Auto, On all day, On constant, off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Override:\u003c\/strong\u003e 1, 2 or 3 hour, Advance\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeating System:\u003c\/strong\u003e Pumped or Gravity\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplies with:\u003c\/strong\u003e EN60730-1, EN60730-2.7, EMC Directive 2004\/108\/EC, LVD Directive 2006\/95\/EC\u003c\/p\u003e\n\u003ch5\u003eWIRING\u003c\/h5\u003e\nN – Neutral In (Clock)\u003cbr\u003eL – Live In (Clock)\u003cbr\u003e1 – HW Off\u003cbr\u003e2 – CH Off\u003cbr\u003e3 – HW On\u003cbr\u003e4 – CH On\u003cbr\u003e\n\u003cp\u003esee instructions for example circuits\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/PR2n.png?v=1491829651\" alt=\"Sangamo Choice PR2n Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/SAN0102D-PR2n.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n Datasheet\"\u003eChoice PR2n Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/Choice-PR2n-Install-Instructions-143793.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n Installation Instructions\"\u003eChoice PR2n Installation Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/Choice-PR2n-User-Instructions-143796.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n User Instructions\"\u003eChoice PR2n User Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=sox781MXXWU\u0026amp;list=PLPVytCcKzzm7ZZi7IaSxS8W8FuH_IlboI\" title=\"Sangamo Choice PR2n YouTube Videos\" target=\"_blank\"\u003eYouTube Video Guides\u003c\/a\u003e\u003c\/p\u003e","published_at":"2022-10-14T11:12:02+01:00","created_at":"2017-04-05T12:26:48+01:00","vendor":"Sangamo Choice","type":"Heating Controls,Brands","tags":["Brand_Choice","Contact Rating_2A","Operations_2 ON\/OFF Operations","Operations_3 ON\/OFF Operations","Outputs_2 Channel","Programming Cycle_24 Hour","Programming Cycle_5\/2 Day","Programming Cycle_7 Day","Type_Programmer"],"price":0,"price_min":0,"price_max":0,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41084813574,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"CHOICE-PR2n","requires_shipping":false,"taxable":true,"featured_image":null,"available":false,"name":"Choice PR2n","public_title":null,"options":["Default Title"],"price":0,"weight":136,"compare_at_price":null,"inventory_quantity":0,"inventory_management":"shopify","inventory_policy":"deny","barcode":"5026961007334","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.sangamo.co.uk\/cdn\/shop\/products\/Choice_PR2n.jpg?v=1530802196"],"featured_image":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/Choice_PR2n.jpg?v=1530802196","options":["Title"],"media":[{"alt":null,"id":3188632912010,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/Choice_PR2n.jpg?v=1530802196"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/Choice_PR2n.jpg?v=1530802196","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/backlit-display.png?v=1530536117\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe Choice PR2n 2 channel programmer is designed for separate control of you heating and stored hot water. The heating and hot water programmes are independent of each other. This gives you the opportunity to save money and control you heating in the most energy saving manner possible.The programmer can be configured for 24 hour, 5\/2 day or 7 day operation, and the flexibility of up to three on\/off timings per day.\u003c\/p\u003e\n\u003cp\u003ePre-programmed but can easily be changed to suit your particular lifestyle. Large and clear to read illuminated display. Attractive modern design that will suit all contemporary homes.Suitable for pumped and gravity fed systems.\u003c\/p\u003e\n\u003cp\u003eFor fully pumped central heating systems using mid position valves, spring return valves or power open, power closed valves or Gravity hot water pumped heating systems with or without motorised valves fitted into the domestic hot water primary circuit.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003e24 hour, 5\/2 day and 7 day selectable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2 or 3 ON\/OFF periods selectable\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1, 2 or 3 hour boost\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAdvance to next programmed event\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAutomatic Summer\/Winter time change\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eStandard wall plate - simple plug in and replace\u003c\/span\u003e\u003cbr\u003ePumped or gravity system selectable\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATION\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 230V AC, 50Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitch Rating:\u003c\/strong\u003e 230V AC, 2(1)Amp (per channel)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact Type:\u003c\/strong\u003e 1B , Micro-Disconnection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e Lithium Cell CR2032\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Protection:\u003c\/strong\u003e IP30\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastics:\u003c\/strong\u003e Thermoplastic, flame retardant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Class:\u003c\/strong\u003e Double\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e For fixed wiring only\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackplate:\u003c\/strong\u003e Industry standard\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 140mm x 87mm x 37mm Clock: 12 hour am\/pm, 1 minute resolution, accuracy +\/- 1.5 sec\/day\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBST\/GMT time change:\u003c\/strong\u003e Automatic\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Cycle:\u003c\/strong\u003e 24hr, 5\/2day or 7day selectable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram On\/offs per day:\u003c\/strong\u003e 2on\/off, 3on\/off selectable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram resolution:\u003c\/strong\u003e 10mins Program Selection: Auto, On all day, On constant, off\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Override:\u003c\/strong\u003e 1, 2 or 3 hour, Advance\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeating System:\u003c\/strong\u003e Pumped or Gravity\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplies with:\u003c\/strong\u003e EN60730-1, EN60730-2.7, EMC Directive 2004\/108\/EC, LVD Directive 2006\/95\/EC\u003c\/p\u003e\n\u003ch5\u003eWIRING\u003c\/h5\u003e\nN – Neutral In (Clock)\u003cbr\u003eL – Live In (Clock)\u003cbr\u003e1 – HW Off\u003cbr\u003e2 – CH Off\u003cbr\u003e3 – HW On\u003cbr\u003e4 – CH On\u003cbr\u003e\n\u003cp\u003esee instructions for example circuits\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/PR2n.png?v=1491829651\" alt=\"Sangamo Choice PR2n Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/SAN0102D-PR2n.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n Datasheet\"\u003eChoice PR2n Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/Choice-PR2n-Install-Instructions-143793.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n Installation Instructions\"\u003eChoice PR2n Installation Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/Choice-PR2n-User-Instructions-143796.pdf?16149532891351856755\" title=\"Sangamo Choice PR2n User Instructions\"\u003eChoice PR2n User Instructions\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=sox781MXXWU\u0026amp;list=PLPVytCcKzzm7ZZi7IaSxS8W8FuH_IlboI\" title=\"Sangamo Choice PR2n YouTube Videos\" target=\"_blank\"\u003eYouTube Video Guides\u003c\/a\u003e\u003c\/p\u003e"}
Product Description

The Choice PR2n 2 channel programmer is designed for separate control of you heating and stored hot water. The heating and hot water programmes are independent of each other. This gives you the opportunity to save money and control you heating in the most energy saving manner possible.The programmer can be configured for 24 hour, 5/2 day or 7 day operation, and the flexibility of up to three on/off timings per day.

Pre-programmed but can easily be changed to suit your particular lifestyle. Large and clear to read illuminated display. Attractive modern design that will suit all contemporary homes.Suitable for pumped and gravity fed systems.

For fully pumped central heating systems using mid position valves, spring return valves or power open, power closed valves or Gravity hot water pumped heating systems with or without motorised valves fitted into the domestic hot water primary circuit.

24 hour, 5/2 day and 7 day selectable
2 or 3 ON/OFF periods selectable
1, 2 or 3 hour boost
Advance to next programmed event
Automatic Summer/Winter time change
Standard wall plate - simple plug in and replace
Pumped or gravity system selectable

Power Supply: 230V AC, 50Hz

Operating Temperature: 0°C to 40°C

Switch Rating: 230V AC, 2(1)Amp (per channel)

Contact Type: 1B , Micro-Disconnection

Battery Type: Lithium Cell CR2032

Enclosure Protection: IP30

Plastics: Thermoplastic, flame retardant

Insulation Class: Double

Wiring: For fixed wiring only

Backplate: Industry standard

Dimensions: 140mm x 87mm x 37mm Clock: 12 hour am/pm, 1 minute resolution, accuracy +/- 1.5 sec/day

BST/GMT time change: Automatic

Program Cycle: 24hr, 5/2day or 7day selectable.

Program On/offs per day: 2on/off, 3on/off selectable

Program resolution: 10mins Program Selection: Auto, On all day, On constant, off

Program Override: 1, 2 or 3 hour, Advance

Heating System: Pumped or Gravity

Complies with: EN60730-1, EN60730-2.7, EMC Directive 2004/108/EC, LVD Directive 2006/95/EC

N – Neutral In (Clock)
L – Live In (Clock)
1 – HW Off
2 – CH Off
3 – HW On
4 – CH On

see instructions for example circuits