{"id":10271900934,"title":"16921","handle":"16921","description":"\u003cp\u003eA very simple to use and cost effective general purpose single channel timer, that is ideal for many applications. An optional panel mount kit is available for when the back box provided is not suitable.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eManual override with automatic return to program. Contact status display\u003cbr\u003e7 day programming by 1 hour captive segments.\u003cbr\u003eTerminals in housing which opens for easy wiring.\u003cbr\u003e200 hour battery reserve\u003cbr\u003eVoltage free 16A changeover contact\u003cbr\u003eSurface, Panel or Din rail mounting\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003cspan\u003e 230V, +10% -15%, 50\/60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e approx. 0.5VA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eChannel (volt-free)\u003c\/strong\u003e\u003cspan\u003e Change-over\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003cspan\u003e 16A resistive (3A voltage free inductive)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eIncandescent Lamp Halogen Lamp\u003c\/strong\u003e\u003cspan\u003e 1,000W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSquirrel-cage Motor\u003c\/strong\u003e\u003cspan\u003e 350W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eTime Base \u003c\/strong\u003e\u003cspan\u003eQuartz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eQuartz Accuracy\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e ≦ 1 sec\/day\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Operating Temperature\u003c\/strong\u003e\u003cspan\u003e -10°C to 50°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Ambient Temperature\u003c\/strong\u003e\u003cspan\u003e -20°C to 60°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e 72mm x 72mm (to IEC 61554)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eConnection by cage terminals, section of conductors\u003c\/strong\u003e\u003cspan\u003e 1 to 6mm2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of protection\u003c\/strong\u003e\u003cspan\u003e IP20 to DIN EN 60529\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003cspan\u003e II (when installed according to regulations)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003cspan\u003e BS EN 60730\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eWIRING\u003c\/span\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eNeutral\u003c\/li\u003e\n\u003cli\u003eLive In (Clock)\u003c\/li\u003e\n\u003cli\u003eNot used – Normally Closed connection\u003c\/li\u003e\n\u003cli\u003eInput (Load) – External link 2 to 4 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eOutput (Load) – Normally Open connection\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/16621_large.png?v=1491829651\" alt=\"Sangamo 16621 Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/DH011D-16921-16922.pdf?5825304391359724611\" title=\"Sangamo 16921 Datasheet\" target=\"_blank\"\u003e16921 Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/16000-Instructions.pdf?12153187550293070958\" title=\"Sangamo 16921 Instructions\" target=\"_blank\"\u003e16921 Instructions\u003c\/a\u003e\u003cspan\u003e [PDF]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r7miYxrvCF0\" title=\"Sangamo 16921 YouTube Video Guide\" target=\"_blank\"\u003eYouTube Video Guide\u003c\/a\u003e\u003c\/p\u003e","published_at":"2017-04-05T12:41:05+01:00","created_at":"2017-04-05T12:41:08+01:00","vendor":"Sangamo DIN \u0026 Panel","type":"Panel Mounted Timers,Time Switches,Brands","tags":["Battery Reserve_200 Hours","Brand_DIN \u0026 Panel","Contact Rating_16A","Operations","Operations_24 ON\/OFF Operations","Outputs_1 Channel","Programming Cycle_7 Day","Type_Standard Time Switch"],"price":0,"price_min":0,"price_max":0,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41085678790,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"16921","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"16921","public_title":null,"options":["Default Title"],"price":0,"weight":205,"compare_at_price":null,"inventory_quantity":0,"inventory_management":"shopify","inventory_policy":"deny","barcode":"5026961006290","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.sangamo.co.uk\/cdn\/shop\/products\/16921.jpg?v=1531130441"],"featured_image":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/16921.jpg?v=1531130441","options":["Title"],"media":[{"alt":null,"id":3188854554762,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/16921.jpg?v=1531130441"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/www.sangamo.co.uk\/cdn\/shop\/products\/16921.jpg?v=1531130441","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eA very simple to use and cost effective general purpose single channel timer, that is ideal for many applications. An optional panel mount kit is available for when the back box provided is not suitable.\u003c\/p\u003e\n\u003ch5\u003eFEATURES\u003c\/h5\u003e\n\u003cp\u003eManual override with automatic return to program. Contact status display\u003cbr\u003e7 day programming by 1 hour captive segments.\u003cbr\u003eTerminals in housing which opens for easy wiring.\u003cbr\u003e200 hour battery reserve\u003cbr\u003eVoltage free 16A changeover contact\u003cbr\u003eSurface, Panel or Din rail mounting\u003c\/p\u003e\n\u003ch5\u003eSPECIFICATIONS\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003cspan\u003e 230V, +10% -15%, 50\/60 Hz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e approx. 0.5VA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eChannel (volt-free)\u003c\/strong\u003e\u003cspan\u003e Change-over\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003cspan\u003e 16A resistive (3A voltage free inductive)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eIncandescent Lamp Halogen Lamp\u003c\/strong\u003e\u003cspan\u003e 1,000W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eSquirrel-cage Motor\u003c\/strong\u003e\u003cspan\u003e 350W\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eTime Base \u003c\/strong\u003e\u003cspan\u003eQuartz\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eQuartz Accuracy\u003cem\u003e (at 20°C)\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e ≦ 1 sec\/day\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Operating Temperature\u003c\/strong\u003e\u003cspan\u003e -10°C to 50°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003ePermitted Ambient Temperature\u003c\/strong\u003e\u003cspan\u003e -20°C to 60°C\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e 72mm x 72mm (to IEC 61554)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eConnection by cage terminals, section of conductors\u003c\/strong\u003e\u003cspan\u003e 1 to 6mm2\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eType of protection\u003c\/strong\u003e\u003cspan\u003e IP20 to DIN EN 60529\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003cspan\u003e II (when installed according to regulations)\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMode of Operation\u003c\/strong\u003e\u003cspan\u003e BS EN 60730\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eWIRING\u003c\/span\u003e\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eNeutral\u003c\/li\u003e\n\u003cli\u003eLive In (Clock)\u003c\/li\u003e\n\u003cli\u003eNot used – Normally Closed connection\u003c\/li\u003e\n\u003cli\u003eInput (Load) – External link 2 to 4 if using a single 230Vac supply\u003c\/li\u003e\n\u003cli\u003eOutput (Load) – Normally Open connection\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/16621_large.png?v=1491829651\" alt=\"Sangamo 16621 Wiring Diagram\"\u003e\u003c\/p\u003e\n\u003ch5\u003eDOWNLOADS\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/DH011D-16921-16922.pdf?5825304391359724611\" title=\"Sangamo 16921 Datasheet\" target=\"_blank\"\u003e16921 Datasheet\u003c\/a\u003e [PDF]\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1900\/0799\/files\/16000-Instructions.pdf?12153187550293070958\" title=\"Sangamo 16921 Instructions\" target=\"_blank\"\u003e16921 Instructions\u003c\/a\u003e\u003cspan\u003e [PDF]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r7miYxrvCF0\" title=\"Sangamo 16921 YouTube Video Guide\" target=\"_blank\"\u003eYouTube Video Guide\u003c\/a\u003e\u003c\/p\u003e"}

16921

Product Description

A very simple to use and cost effective general purpose single channel timer, that is ideal for many applications. An optional panel mount kit is available for when the back box provided is not suitable.

Manual override with automatic return to program. Contact status display
7 day programming by 1 hour captive segments.
Terminals in housing which opens for easy wiring.
200 hour battery reserve
Voltage free 16A changeover contact
Surface, Panel or Din rail mounting

Supply Voltage 230V, +10% -15%, 50/60 Hz
Power Consumption approx. 0.5VA
Channel (volt-free) Change-over
Switching Capacity 16A resistive (3A voltage free inductive)
Incandescent Lamp Halogen Lamp 1,000W
Squirrel-cage Motor 350W
Time Base Quartz
Quartz Accuracy (at 20°C) ≦ 1 sec/day
Permitted Operating Temperature -10°C to 50°C
Permitted Ambient Temperature -20°C to 60°C
Dimensions 72mm x 72mm (to IEC 61554)
Connection by cage terminals, section of conductors 1 to 6mm2
Type of protection IP20 to DIN EN 60529
Class of Protection II (when installed according to regulations)
Mode of Operation BS EN 60730

  1. Neutral
  2. Live In (Clock)
  3. Not used – Normally Closed connection
  4. Input (Load) – External link 2 to 4 if using a single 230Vac supply
  5. Output (Load) – Normally Open connection

Sangamo 16621 Wiring Diagram